Compaq HSG80 - StorageWorks RAID Array Controller Specifiche Pagina 303

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 396
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 302
7–107
Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guide
These steps use DISK10000 as an example.
1. Delete all containers to which the disk belongs.
2. Make the disk transportable.
SET DISK10000 TRANSPORTABLE.
3. Initialize the disk.
INIT DISK10000
4. Delete the disk.
DELETE DISK10000
5. Move DISK10000 to the failedset’s vacant slot.
Example
This example shows how to enable the automatic spare feature:
SET FAILEDSET AUTOSPARE
This example shows how to disable the automatic spare feature:
SET FAILEDSET NOAUTOSPARE
See also
SHOW FAILEDSET
Vedere la pagina 302
1 2 ... 298 299 300 301 302 303 304 305 306 307 308 ... 395 396

Commenti su questo manuale

Nessun commento