7–104
CLI Commands
If any of the setpoints assigned to a slave EMU do not match the corresponding
setpoints assigned to the master EMU, the slave EMU settings change to match the
corresponding master EMU settings.
Refer to the enclosure documentation for detailed information about setting the EMU
temperature set points.
FANSPEED=HIGH
FANSPEED=AUTOMATIC (Default)
Sets the speed at which the fan operates.
Select FANSPEED=HIGH to force the fans in all connected cabinets to operate at
high speed continuously.
Table 7–5. EMU Set Point Temperatures
ºC ºF ºC ºF ºC ºF ºC ºF ºC ºF
0 3210502068308640104
1 3411522170318841106
2 4612542272329042108
3 3713552373339143109
4 3914572475349344111
5 4115592577359545113
6 4316612679369746115
7 4517632781379947117
8 46186428823810048118
9 48196629843910249120