Compaq HSG80 - StorageWorks RAID Array Controller Specifiche Pagina 219

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 396
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 218
7–23
Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guide
ADD SPARESET
Adds a disk drive to the spareset.
Syntax
ADD SPARESET disk-name
Parameter
disk-name
Indicates the name of the disk drive being added to the spareset. Only one disk drive
can be added to the spareset with each ADD SPARESET command.
Example
To add a disk drive named DISK20200 and DISK30300 to a spareset, type:
ADD DISK DISK20200 2 2 0
ADD DISK DISK30300 3 3 0
ADD SPARESET DISK20200
ADD SPARESET DISK30300
See also
DELETE SPARESET
SET FAILEDSET
SHOW SPARESET
SHOW STORAGESETS
Vedere la pagina 218
1 2 ... 214 215 216 217 218 219 220 221 222 223 224 ... 395 396

Commenti su questo manuale

Nessun commento