Compaq HSG80 - StorageWorks RAID Array Controller Specifiche Pagina 283

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 396
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 282
7–87
Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guide
SELFTEST
controller
Flushes the data from the specified controllers write-back cache (if present) and shuts
down the controller. It then restarts the controller in self-test mode. Press the
controller reset (//) button to take the controller out of self-test mode.
Syntax
SELFTEST controller
Parameters
controller
The controller parameter indicates which controller is to perform the self-test
program. Specify OTHER_CONTROLLER or THIS_CONTROLLER.
Switches
IGNORE_ERRORS
NOIGNORE_ERRORS (Default)
Instruct the controller how to respond to write-back cache errors.
CAUTION: The IGNORE_ERRORS switch might cause data to remain in
write-back cache. See “Fault-Tolerance for Write-Back Caching,”
page 2–11, for considerations when implementing write-back cache. Do
not perform any hardware changes until the controller flushes the
cache.
Specify IGNORE_ERRORS to instruct the controller to ignore any write-back cache
errors. Such errors can result from data contained within write-back cache unable to
be written to the devices or lost data errors.
Specify NOIGNORE_ERRORS to instruct the controller not to run the self-test
program if the write-back cache errors are detected.