Compaq HSG80 - StorageWorks RAID Array Controller Specifiche Pagina 179

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 396
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 178
6–11
Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guide
6. Verify the unit configuration and switches. Use the following command:
SHOW
unit-number
Example
The following example shows the commands you would use to create Stripe1, a three-
member striped mirrorset that comprises Mirr1, Mirr2, and Mirr3, each of which is a
two-member mirrorset:
ADD MIRRORSET Mirr1 disk10000 disk20000
ADD MIRRORSET Mirr2 disk30000 disk40000
ADD MIRRORSET Mirr3 disk50000 disk60000
ADD STRIPESET Stripe1 Mirr1 Mirr2 Mirr3
INITIALIZE Stripe1 CHUNKSIZE=default
ADD UNIT D101 Stripe1
SHOW Stripe1
SHOW D101
For more detailed information on configuring a striped mirrorset, refer to Chapter 7,
“CLI Commands.”
Vedere la pagina 178
1 2 ... 174 175 176 177 178 179 180 181 182 183 184 ... 395 396

Commenti su questo manuale

Nessun commento