Compaq HSG80 - StorageWorks RAID Array Controller Specifiche Pagina 221

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 396
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 220
7–25
Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guide
Examples
To create a stripeset named STRIPE1 with three disks: DISK10000, DISK20100, and
DISK30200, enter:
ADD DISK DISK10000 1 0 0
ADD DISK DISK20100 2 1 0
ADD DISK DISK30200 3 2 0
ADD STRIPESET STRIPE1 DISK10000 DISK20100 DISK30200
To create a stripeset named STRIPE1 and then create a logical unit from it, type:
INITIALIZE STRIPE1
ADD UNIT D103 STRIPE1
This example shows how to create a two-member striped mirrorset (a stripeset whose
members are mirrorsets), and how to create a logical unit from it. Because you can
initialize the stripeset, you do not need to individually initialize the mirrorsets.
ADD DISK DISK10000 1 0 0
ADD DISK DISK20100 2 1 0
ADD DISK DISK30200 3 2 0
ADD DISK DISK40300 4 3 0
ADD MIRRORSET MR1 DISK10000 DISK20100
ADD MIRRORSET MR2 DISK30200 DISK40300
ADD STRIPESET STRIPE1 MR1 MR2
INITIALIZE STRIPE1
ADD UNIT D104 STRIPE1