Honeywell DE Fields and Values
86 34-ST-25-20 MC Toolkit User Manual Release 0
7/03
Dialog Field Value
DE Configure Span Floating point (URV – LRV)
(continued) Linearization (STT only) Linear Non-Linear
Conformity (ST only) Linear Square Root
Auxiliary
Configure
(STT only)
Critical Status Latching Enabled Disabled
NAMUR Enabled Disabled
CJ Compensation Internal External
CJ Temperature Floating point
Write Protection Enabled Disabled
Password Write protection password (4 digits)
Change Password
(STT only)
New Password 4 digits
Confirm New Password 4 digits
Monitor Input Transmitter input in engineering units (floating point)
Output Transmitter output in percent (floating point)
SV Secondary variable (floating point)
Device Status Gross Status Critical Non-Critical
Invalid
Database
Critical Critical status strings
Non-Critical Non-critical status strings
Local Meter (ST
only)
Meter Hardware Full Functional
Meter
Meter, NO
Local Span or
Zero
No Meter, Local
Span & Zero
No Meter
Installed
Meter Units %
inH2O @ 39F
mmHg @ 0C
psi
kPa
mPa
mBar
bar
g/c
kg/c
mmH2O @ 4C
mHg @ 0C
mH2O 4C
GPM
GPH
Custom
Custom Units 8 characters
Flow EU Upper Value Floating point
Flow EU Lower Value Floating point