4-14 Compaq AlphaServer ES40 Owners Guide
Command Conventions
Observe the following conventions for entering RMC commands:
Enter enough characters to distinguish the command.
NOTE: The reset and quit commands are exceptions. You must enter the
entire string for these commands to work.
For commands consisting of two words, enter the entire first word and at
least one letter of the second word. For example, you can enter disable a
for disable alert.
For commands that have parameters, you are prompted for the parameter.
Use the Backspace key to erase input.
If you enter a nonexistent command or a command that does not follow
conventions, the following message is displayed:
*** ERROR - unknown command ***
If you enter a string that exceeds 14 characters, the following message is
displayed:
*** ERROR - overflow ***
Use the Backspace key to erase input.