Compaq 3100ES - Smart Array RAID Controller Guida Utente Pagina 144

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 162
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 143
Compaq Smart Array 431 Controller User Guide
continued
1789 Slot x Drive Array SCSI Drive(s) Not
Responding. Check cables or replace the
following SCSI drives: SCSI Port (y):
SCSI ID (x)
Select to continue - drive array will
remain disabled.
Select to failed drives that are not
responding - Interim Recovery Mode will be
enabled if configured for fault tolerance.
This message indicates that previously
operating drives are missing or inoperative
following a cold or warm reset. Turn off system
and check cable connections. If cables are
connected, replace the drive. Press to restart
the computer with the drive array disabled.
-Or-
If you do not want to replace the drives now,
press .
: Message 1788 might also be displayed inadvertently due to a bad power cable connection to the
drive or a defective SCSI cable. If this message was due to a bad power cable connection, repair the
connection and press . If this message is not eliminated by pressing , run the Drive Array Advanced
Diagnostics Utility.
-OR-
If this message was not due to a bad power cable connection, and the drive was not replaced, this could
indicate a defective SCSI cable. Contact your Authorized Compaq Service Provider.
Vedere la pagina 143
1 2 ... 139 140 141 142 143 144 145 146 147 148 149 ... 161 162

Commenti su questo manuale

Nessun commento