Operation and Management
57MSA1000 Reference Guide
When a drive fails, the online spare becomes active and begins rebuilding as a
replacement drive. After the online spare has completed Automatic Data
Recovery (the Online indicators will be continuously lit), replace the failed
drive with a new replacement drive. Do not replace the failed drive with the
online spare. The system will automatically rebuild the replacement drive and
reset the spare drive to an available state.
If you replace a drive while the system is off, it may be necessary to rebuild
the replaced drive.
Up to one half of the drives in a RAID 1+0 array can be replaced at the same
time.