Compaq, the Compaq logo, and DIGITAL registered in United States Patent and Trademark Office. EK–370XB–IG. B01
StorageWorks is a trademark of Compaq Computer Corporation. December 1998
© 1998 Compaq Computer Corporation. All rights reserved. Printed in the U.S.A.
Compaq StorageWorks
BA370 Enclosure Universal
Mounting Kit (DS–BA370–XB)
Installation Guide
This document describes how to install a BA370 enclosure in a Enterprise Storage Array (ESA) 12000 or SW600 cabinet
using a BA370 enclosure universal mounting kit (DS–BA370–XB). The ESA 12000 cabinet is a RETMA cabinet; the
SW600 cabinet is a metric cabinet. Either one or two BA370 enclosures can be installed in each of these cabinets.
Compaq recommends installing the first BA370 enclosure as low as possible in the cabinet for stability purposes. The size
of the opening required for installing a BA370 must be at least 30.5 in (774.7 mm) high and 19 in (482.6 mm) wide.
Universal Mounting Kit Contents
Use Table 1 to verify that all BA370 enclosure universal mounting kit parts required for a RETMA or metric cabinet
installation are available.
Note
Note
Since the BA370 enclosure universal mounting kit is designed for use in cabinets other than those provided by
Compaq, there will be parts left over upon completing the installation process.
For easy identification, a component part number is stamped on each bracket and plate.
BA370 Enclosure Specifics
The following special considerations aid in the proper installation and operation of a BA370 enclosure:
Operating Temperature
— 10°C to 40°C (50°F to 104°F) is the recommended operating environment.
Overtemperature Automatic Shut-Off
— Internal circuitry monitors the operating temperature of the enclosure. If
the operating temperature exceeds allowable limits, audible and visual warnings are provided. Unless the
overtemperature condition is resolved within approximately 8 minutes, the enclosure begins an automatic shutdown
sequence.
Table 1 Mounting Kit Parts List
Description Qty Description Qty
Left Mounting Plate (70–40038–01) 1 10-32 x 1/2 in Flat Head Machine Screw
(90–06073–02)
4
Right Mounting Plate (70–40038–02) 1 6-32 x 3/8 in TRUSS Head Screw (90–11409–03) 1
BA370 Mounting Bracket (70–60052–01) 4 10-32 Clip U-Nuts (90–06073–02) 12
LED Bracket Assembly (70–40039–01) 1 Cable Ties (90–11456–01) 18
Cover Plate (74–60152–01) 1 SEMS Screws:
8-32 x 1/4 in Pan Head (90–09545–00)
10-32 x 5/8 in Pan Head (12–21368–02)
8
31
Vedere la pagina 0
1 2 3 4 5 6 7 8 9 10

Sommario

Pagina 1 - Installation Guide

Compaq, the Compaq logo, and DIGITAL registered in United States Patent and Trademark Office. EK–370XB–IG. B01StorageWorks is a trademark of Compaq Co

Pagina 2 - Preliminary Information

10 Installing the Upper EnclosureComplete the procedures in Table 6 and Table 7 to install a BA370 enclosure in the upper location.WARNING!The full

Pagina 3 - CXO6591B

2 •Air Flow — Compaq recommends that no equipment should be mounted behind the enclosure, allowing adequate air flow within the cabinet.•Mechanical

Pagina 4 - CXO6592B

3 Installing the Left-Lower Mounting PlateComplete the procedure in Table 2 or Table 3 to install the left-lower mounting plate in the cabinet. Refe

Pagina 5

4 Installing the Right-Lower Mounting PlateComplete the procedure in Table 4 or Table 5 to install the right-lower mounting plate in the cabinet. Re

Pagina 6 - CXO6593B

5 Installing the LED Bracket and Mounting Brackets on a BA370 EnclosureComplete the procedure in Table 6 to install the LED bracket assembly and enc

Pagina 7 - CXO6596B

6 Figure 3 Installing the LED Bracket and Enclosure Mounting BracketsInstalling the Lower EnclosureComplete the procedure in Table 7 to install the

Pagina 8

7 Table 7 Enclosure Installation Procedure 1. Remove all components from the BA370 enclosure being mounted.2. For cabinets with stabilizer legs:a. P

Pagina 9

8 Installing the Upper EnclosureFor RETMA cabinets, complete the procedures in Table 8 and Table 10, and then the procedures in Table 6 and Table 7

Pagina 10

9 Installing the Right-Upper Mounting PlateComplete the procedure in Table 10 or Table 11 to install the right-upper mounting plate in the cabinet.